Products > Embedded Products > CPCI/CPCIe > Power Supplies > Modular power supply
 
 

3U Power Supply

3U 200 watt modular power supply for CPCI/CPCIe with P47 power connector, AC input.

Form Factor: 3U
Part Number: OSS-CPCI-3U-PS-200

Product Features

  • 200 watt, quad output in 3U x 8HP form factor
  • Current sharing and internal OR-ing diodes for N+1 redundancy
  • Fully compliant with PICMG CompactPCI specifications
  • High current 5V and 3.3V outputs
  • CompactPCI package requires on 15 cfm of external cooling air
  • Modular with P47 power connector
  • Outputs: +5V @ 25A, +3.3V @ 30A, +12V @ 5.5A, -12V @ .5A
Specifications

AC Input 90-264 Vac continuous range, 47 to 63 Hz
Power factor 0.99 typical at full load. Meets EN61000-3-2
Inrush Cold start ac current is less than 15 A at 115 Vac, and 60 A at 230 Vac. Limited by thermistor
Brownout Protection Holds regulation to 85 Vac (30 seconds maximum)
Holdup Time 16 ms minimum after removal of power at full load. 10 ms minimum for cPCI 200s
Efficiency 70% typical
EMI: Conducted RFI Meets FCC Part 15, Subpart J, class A; EN55022 class A; CISPR 22 class A
Fail # Signal TTL compatible signal. Signal goes low under the following conditions:
  Outputs #1 or #2 fail
  an overcurrent condition on outputs #1, #2, or #3
  an overtemperature shutdown
  an overvoltage shutdown
  an ac input failure (5 ms warning before outputs shutdown)
Output  
Line and Load Regulations +/-2% over input range and 0 to 100% load change
Ripple & Noise 1% p-p or 50 mV, whichever is greater
  measured at mating connector with 20 uF
Remote Sense open sense lead protection
Temperature Coefficient (Outputs #1 and 2): 0.03% per degree centigrade
Stability 0.1% over 8 hours after 30 minutes warm-up
Transient Response (outputs #1 and 2):
  Output voltage returns to within 1% in less than 1 ms for a 50% load change.
  Peak transient does not exceed 5%
Overvoltage Protection (outputs #1 and 2):
  Protects load against power supply induced overvoltage
  Trip-point is factory set so that output voltage cannot exceed 136% of nominal
  Input power must be recycled to reset.
Overload Protection All outputs are protected against overload and short circuit
  automatic recovery upon removal of fault
DEG # Signal TTL compatible signal. Signal goes low 20 degrees C before an overtemperature shutdown
Fail LED Amber LED illuminates upon a failure condition as per series specifications
Status LED Green LED illuminates with no presence of any failure condition
Remote Enable Contact closure to the negative sense line or a TTL level "0" turns off dc outputs
Redundancy Built-in ORing diodes, slope program current sharing on all outputs, and self aligning connector provide hot swap and N+1 capabilities.
  Current sharing remains within 10% of the unit's full output rating while units are in thermal equalibrium
Reverse Voltage protected against reverse voltage up to supply current rating, except for reverse voltage on output #4
Environmental  
Cooling 15 cfm, 225 lfm airflow required for cooling
Output Isolation Isolated from ground 50 Vdc (leakage current <20 uA)
Thermal Protection Shuts down power supply if overheated
  Automatic recovery
Temperature Range 0 to 40 degrees centigrade at full ratings
  derate 2.5% per degree centigrade from 40 degrees to 70 degrees centigrade
  unit will start up at -20 degrees centigrade
MTBF 421,408 hours
Miscellaneous  
Safety Agency Approvals Models are approved to UL1950; CSA 22.2 #234
  IEC 950 and TUV EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive)
Warranty Two year guarantee includes labor and parts
  Guarantee applies to operation at full published specifications at the end of 2 years
Options  
Low Leakage "L" option: Leakage current less than 0.5 mA per unit. Will require additional filtering for compliance to EMI specifications.
Mechanical Dimensions 3U x 8HP W, 160 mm board depth
  Utilizes a 47-pin modular connector in accorgance with PICMG Power Interface Specification 2.11