Products > CPCI/CPCIe > Power Supplies > 300W Power Supply
 
 

3U Power Supply

3U 300 watt modular power supply for CPCI/CPCIe with P47 power connector, AC input.

Form Factor: 3U
Part Number: OSS-CPCI-3U-PS-300

Product Features

  • 300 watt, quad output in 3U x 8HP form factor
  • Current sharing and internal OR-ing diodes for N+1 redundancy
  • Fully compliant with PICMG CompactPCI specifications
  • High current 5V and 3.3V outputs
  • CompactPCI package requires on 15 cfm of external cooling air
  • P47 power connector
  • Outputs: +5V, +3.3V, +12V, -12V

Specifications

Input
AC Input 90-264V, 3.5A max 47 to 63 Hz.
Power Factor 0.99 corrected at AC 90-264V input
Inrush Thermistor soft start. ~25*C AC cold start current
  15Apk @ AC 115V
  30Apk @ 230V
Transient Protection MOV. Withstands transients as specified
  by IEEE C62.41 3KV (differential and common |mode)
Efficiency 70% typical at AC 115V, full load
Redundant/Hot Swap Full power N+1 redundant, hot swap capable
   
Output  
Power Output +5V @ 40A, +3.3V @ 40A, +12V @ 10A, -12V @ 2A
Line Regulation At the Sense Point, Over Full AC Input Range
  <+-.05% sense lead connected.
Load Regulation +-1% typical for V1,V2;+-2%for V3;+-5% for V4
Minimum Loading not required
Stability Output drift +-0.02%/*C, 0*-50*C after 20 minute warm-up.
Temp Coefficient <+-0.02%/*C, 0*-50*C after 20 minute warm-up
Ripple & Noise For all outputs, 50mV max or 1% peak-to-peak |nominal, whichever is greater
Remote Sense V1, V22 outputs compensate for up to .25V total
  line drop in the load cables. Outputs are internally sensed if |leads are opened
Current Sharing V1, V2, V3 Outputs. Droop method current share for V4
Hold-up time Outputs remain in regulation >18msec minimum following loss of AC power at low line, full load
Overvoltage Protection Non-crowbar type. Any output that exceeds 25% +-10% of nominal Vout will cause all outputs to latch off. Remote inhibit, enable or AC input recycle required to set.
   
Signals, Indicators and Controls  
Remote Enable Enabled by closed circuit or TTL logic 0. Disabled by closed circuit or TTL logic 1.
Remote Inhibit Enabled by closed circuit or TTL logic 1. Disabled by closed circuit or TTL logic 0.
   
Environmental  
Temperature Range 0 degrees to 50 degrees C at full load with specified airflow
Cooling A minimum of 60 cfm / 800 lfm direct forward airflow required to achieve fill rated power and specified MTBF.
Relative Humidity Up to 90% RH, non-condensing
Operational Vibration 2.0G peak, 5-500Hz along three orthogonal axis
Storage Temperature -40 to 85 degrees C
MTBF Designed for 150,000 hours at 25 degrees C