| Dimensions: |
86mm tall, 150mm wide, 220mm
deep |
| Input |
|
| Voltage (sinusoidal) |
Full range — 90~264 VAC (with +-10% tolerance) |
| Frequency |
47Hz — 63Hz (=-3Hz) |
| Steady-state current |
6/3 amps maximum at any low/high range input
voltage |
| Inruch Current |
60/80 amps @ 110/220VAC (at 25 degrees ambient
cold start) |
| Power factor correction |
PFC can reach the target of 95% @110V, full
load, following the standard of IEC 1000-3-2, class D |
| |
|
| Output |
|
| Power Output |
+5V @ 25A, +12V @ 16A, -5V @ .5A, -12V @ .5A,
+3.3V @ 14A, +5VSB @ 1.2A |
| Regulation |
All output voltages @ +-50mV |
| Ripple and noise |
+5V @ 50mV (P-P), +12V @ 120mV (P-P), -5V
@ 120mV (P-P), -12V @ 150mV (P-P), +3.3V @ 50MV (P-P), +5VSB
@ 50mV (P-P) |
| Overshoot |
Any overshoot at turn on or off shall be
less than 15% of the nominal voltage value. |
| Efficiency |
Power supply efficiency typical 63% at 115V
full load. |
| Remote on/off control |
The power supply DC outputs (with the exception
of +5VSB) shall be enabled with an active-low TTL-compatible
signal ("PS-ON"). When PS-ON is pulled to TTL low
the DC outputs are to be enabled. When PS-ON is pulled to
TTL high or open circuited the DC outputs are to be disabled. |
| |
|
| Environment |
|
| Temperature |
Operating: 0 to 40 degrees C |
| |
Non-operating: -20 to 80 degrees C |
| |
Safety regulation: Applied at room temperature
(25 degrees C) |
| Humidity |
Operating: 20% to 80% |
| |
Non-operating: 10% to 90% |
| Insulation resistance |
Primary to secondary: :20 meg. ohm min. 500
VDC |
| |
Primary to Frame Gnd: :20 meg. ohm min. 500
VDC |
| Dielectric withstanding voltage |
|
| For approval purpose |
|
| |
Primary to secondary: :3KVAC for 1 min. |
| |
Primary to Frame Gnd: :1500 VAC for 1 min. |
| For production purpose: 100% test |
|
| |
Primary to Frame Gnd: :1500 VAC for 1 sec |
| |
Cut off current: 15mA |
| Leakage Current |
3.5mA at nominal voltage 250 VAC |