Products > Servers > 1U 5500-Series Server
 

 

1U 5500-Series Server

1U NEBS-compliant server is equipped with Intel® 5500 series Server Board, two Intel® Xeon® quad or six-core processors, a 550W AC or DC output power supply, a fixed 2½" internal drive shuttle, and either a 3½" hot swappable drive shuttle.

Form Factor: 1U
Part Number:
OSS-MB-1U-SYS-5520-xxx-2HD-550W-AC
OSS-MB-1U-SYS-5520-xxx-2HD-550W-DC

Product Features

  • Supports dual Intel® Xeon® Nehalem or Westmere processors
  • Single 550W AC or DC power supply or dual 750W AC or DC power supplies
  • NEBS-certified
     

Specifications

Intel® Server Board 5500 Series • Dual Intel® Xeon® 5500 or 5600 series processors
• Dual Gigabit Ethernet connections
• Integrated Graphics
• 12 DDR3 DIMM sockets
• SATA RAID level 0/1/10 with optional RAID 5
• 6 SATA ports
CPU • L5638 2.0Ghz (Westmere) 6-core, 60W
• L5646 2.4Ghz (Westmere) 6-core, 80W
• E5508 2.0Ghz (Nehalem) quad-core, 38W
• E5540 2.53Ghz (Nehalem) quad-core, 80W
Input/Output PCI: • 1 PCI Express x16 Gen 2 slot
Storage Capacity

• 1 internal fixed 2½" drive
• 1 hot swappable 3½" drive shuttle

Dimensions:

17" wide x 1.75" high x 21" deep

Cooling Fans: Six 23CFM fans plus power supply fan providing front-to-rear airflow
Air Filter: • Removable air filter bracket with thumb screws
• Air filter: One 30 ppi (pores per inch) air filter, open cell, polyfoam, UL 900 rating
Chassis: • USB connector on front panel
• Dual DC input on rear with internal Or-ing board (DC version)
• Cable hold-down support on rear of enclosure
Weight: <20kg
Overall MTBF: 100,000 hours across all components
Construction: Clear zinc plated (20 and 18 gauge) cold rolled steel
Power Supply: 550W input power supply
AC:

Single input on rear panel

-48VDC:

Dual input on rear panel

Outputs: +5 @ 30A, +12V @ 11A, -12V @ 1A, +3.3V @ 22A, -5V @ 1A
Temperature Range

0° to 50°C (32° to 122°F)

Relative Humidity

10 to 90% non-condensing

Shock

30g acceleration peak (11ms pulse)

Vibration

5-17 Hz 0.5” double amplitude; displacement; 7-2000Hz, 1.5g acceleration

Damp Heat (Humidity)

DIN EN 60068-2-30, Method Db Variant 2

Random Vibration

DIN EN 60068-2-64 dated 2007-12, Class B

Sine Vibration
  • Frequency range: 5 HZ to 55 Hz
  • Excursion: 0.15 mm, constant amplitude, (corresp. to 1.8 g at 55 Hz)
  • Frequency range: 55 Hz to 150 Hz
  • Acceleration: 0.5 g, constant
  • Test speed: approx. 1 octave per minute, logarithmic
  • Stress duration: 12 minutes on each of three perpendicular axes
Agency

Meets or exceeds the following requirements:
• Certified, FCC Class A
• Safety UL/CSA-60950-1, EN60950-1,
IEC60950-1, CB Scheme with all country
deviations, IEC825-1, 2, CFR21 part 1040,
CNS1436, GB4943
• RFI/EMC EN55022 Class A, 47 CFR 15B
Class A, ICES-003 Class A, VCCI Class
A, AS/NZ 3548 Class A, CNS 13438 Class
A, KSC 5858 Class A, GB9254 Class A,
EN61000-4-6, GB17625.1, EN6100-3-3
• Immunity EN55024, IEC 61000-4-2, IEC
61000-4-3, IEC 61000-4-4, IEC 61000
4-5, IEC 61000-4-6, IEC-61000-4-8, IEC
61000-4-11
• Regulatory markings CE, FCC, ICES-003,
VCCI, UL/cUL
• Certified to NEBS level 3