Provides up to 212TB of fast Flash storage for up to three servers and is designed to meet Open Compute Project specifications.
The 2xOpenU Flash Storage Expansion (OCP-FSA) provides up to 212TB of direct attached Flash storage through up to sixty-three Flash Memory add-in boards in x8 Gen3 slots. The 2xOU FSA cables to one to three host computers through PCIe x16 Gen3 connections operating at 128Gb/s bandwidth. The low-profile, half-length host cable adapters support low latency and extreme bandwidth to the Flash Memory.
Enclosure | • Dimensions: 21”W x 3.7” H x 34.5”D or 536mm W x 94.5mm H x 878mm D • Supports up to 63 half-length, half-height, single-slot PCIe x8 NAND FLASH boards • All boards face the front of the chassis with the front row of NAND flash boards having I/O bracket access • Up to three PCIe 3.0 x16 cable interfaces on the front of the chassis • 6 removable fans accessed using the slide-out tray • Cable management using hinged cable arm to support slide-out access to all Flash cards |
Main Backplane | One to three PCIe x16 cable inputs and up to 19 PCIe x8 Flash slots • All x8 connectors are “open back” style for maximum flexibility with Flash cards up to PCIe x16 • High-speed interconnects to the rear backplane • Three PLX PEX 8796 primary switches manage PCIe interconnects from cables to canisters • On board IPMI System Monitor • Connected to the chassis bus-bar power distribution system |
Rear Backplane | • 44 additional PCIe x8 Flash slots in 2 ranks of 22 each • All x8 connectors are “open back” style for maximum flexibility with Flash cards up to PCIe x16 • High-speed interconnects to the main backplane • Four secondary PLX PEX 8796 PCIe 3.0 switches provide fan out to all 44 x8 slots |
Power | • Supports Flash cards up to 50W each • Total power up to 3780W supported form OCP rack power delivery system • All +12V power rails shared on copper bus bar delivery system to all backplanes |
Front Indicator Panel | • Front panel LEDs for System power, IPMI status, Alarm, Fan Status and 64 Slot Status indicators • 2x RJ45 connectors for IPMI v2.0 System Monitor • 1x DB-9 serial port for IPMI network configuration |
System Monitoring | Fully IPMI v2.0 compliant monitoring, control & alarming system Temperature • Monitors inlet & exhaust temps • Fan speed auto adjusts by temp • Alarm set-points for over temp Fans • Monitors all system fan tachometers • Pulse Width Modulation fan speed control • Alarms for slow or failed fans Power • Monitors output voltage rails • Alarms for voltages out of range • Alarms for supply failure Add-in Cards • Optionally monitors add-in card I2C SM bus (if used) • Optional Alarms for abnormal card telemetry Interface • Command Line Interface or web Graphical User Interface • Supports SNMP and RCMP+ external interfaces |
Cooling | • Six 80 x 80 x 38mm fans center mounted in the enclosure • All fans are 143CFM each in pull-through configuration • All fans PWM monitored and speed controlled by the IPMI system monitor • Fans support hot-swap when the main tray is extended past the fans |
Operating Environment | • Temperature range: • Operating: 10°—35°C • Storage: -40°—85°C • Humidity range: • Operating: 20% to 80% relative (non-condensing) • Non-operating: 5% to 95% relative (non-condensing) • Altitude range: • Operating: 0 to 10,000 ft. • Storage: 0 to 50,000 ft. |
Agency Compliance | Designed to meet the following agency certifications with testing currently pending: • FCC - Part 15 of the FCC Rules, Class A, 47CFR • Canada ICES-003, issue 4, Class A • UL/IEC 60950-1 • Canada: CSA C22.2 No. 60950-1 • Argentina: IEC60950-1 • Japan: VCCI, Class A • Australia/New Zealand AS/NZS CISPR 22, Class A • IEC 60950-1 (CB Certificate and CB Test Report) • CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3) • CISPR 22, CISPR 24, Class A • CE Emissions 2004-108EC • RoHS compliance (Directive 2002/95/EC) • CCN NWGQ, NWGQ7 |