Provides up to 212TB of fast Flash storage for up to three servers and is designed to meet Open Compute Project specifications.

Find a Distributor

The 2xOpenU Flash Storage Array (OCP-FSA) provides up to 212TB of direct attached Flash storage through up to sixty-three Flash Memory add-in boards in x8 Gen3 slots. The 2xOU FSA cables to one to three host computers through PCIe x16 Gen3 connections operating at 128Gb/s bandwidth. The low-profile, half-length host cable adapters support low latency and extreme bandwidth to the Flash Memory.

Enclosure • Dimensions: 21”W x 3.7” H x 34.5”D or 536mm W x 94.5mm H x 878mm D
• Supports up to 63 half-length, half-height, single-slot PCIe x8 NAND FLASH boards
• All boards face the front of the chassis with the front row of NAND flash boards having I/O bracket access
• Up to three PCIe 3.0 x16 cable interfaces on the front of the chassis
• 6 removable fans accessed using the slide-out tray
• Cable management using hinged cable arm to support slide-out access to all Flash cards
Main Backplane One to three PCIe x16 cable inputs and up to 19 PCIe x8 Flash slots
• All x8 connectors are “open back” style for maximum flexibility with Flash cards up to PCIe x16
• High-speed interconnects to the rear backplane
• Three PLX PEX 8796 primary switches manage PCIe interconnects from cables to canisters
• On board IPMI System Monitor
• Connected to the chassis bus-bar power distribution system
Rear Backplane • 44 additional PCIe x8 Flash slots in 2 ranks of 22 each
• All x8 connectors are “open back” style for maximum flexibility with Flash cards up to PCIe x16
• High-speed interconnects to the main backplane
• Four secondary PLX PEX 8796 PCIe 3.0 switches provide fan out to all 44 x8 slots
Power • Supports Flash cards up to 50W each
• Total power up to 3780W supported form OCP rack power delivery system
• All +12V power rails shared on copper bus bar delivery system to all backplanes
Front Indicator Panel • Front panel LEDs for System power, IPMI status, Alarm, Fan Status and 64 Slot Status indicators
• 2x RJ45 connectors for IPMI v2.0 System Monitor
• 1x DB-9 serial port for IPMI network configuration
System Monitoring Fully IPMI v2.0 compliant monitoring, control & alarming system
Temperature
• Monitors inlet & exhaust temps
• Fan speed auto adjusts by temp
• Alarm set-points for over temp
Fans
• Monitors all system fan tachometers
• Pulse Width Modulation fan speed control
• Alarms for slow or failed fans
Power
• Monitors output voltage rails
• Alarms for voltages out of range
• Alarms for supply failure
Add-in Cards
• Optionally monitors add-in card I2C SM bus (if used)
• Optional Alarms for abnormal card telemetry
Interface
• Command Line Interface or web Graphical User Interface
• Supports SNMP and RCMP+ external interfaces
Cooling • Six 80 x 80 x 38mm fans center mounted in the enclosure
• All fans are 143CFM each in pull-through configuration
• All fans PWM monitored and speed controlled by the IPMI system monitor
• Fans support hot-swap when the main tray is extended past the fans
Operating Environment • Temperature range:
          • Operating: 10°—35°C
          • Storage: -40°—85°C
• Humidity range:
          • Operating: 20% to 80% relative (non-condensing)
          • Non-operating: 5% to 95% relative (non-condensing)
• Altitude range:
          • Operating: 0 to 10,000 ft.
          • Storage: 0 to 50,000 ft.
Agency Compliance Designed to meet the following agency certifications with testing currently pending:
• FCC - Part 15 of the FCC Rules, Class A, 47CFR
• Canada ICES-003, issue 4, Class A
• UL/IEC 60950-1
• Canada: CSA C22.2 No. 60950-1
• Argentina: IEC60950-1
• Japan: VCCI, Class A
• Australia/New Zealand AS/NZS CISPR 22, Class A
• IEC 60950-1 (CB Certificate and CB Test Report)
• CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
• CISPR 22, CISPR 24, Class A
• CE Emissions 2004-108EC
• RoHS compliance (Directive 2002/95/EC)
• CCN NWGQ, NWGQ7